3.3 Analog Controller Operating Instructions

WARNING

Before pressing the power switch to the ON position, ensure that the frypot is

properly filled with oil. See Section 3.1.

1.Verify that the thermostat knob is set to the desired cooking temperature. For split-vat units, set both knobs.

2.Press the power switch to the ON position. The POWER light will illuminate. For split-vat units, both power switches must be placed in the ON position if both vats are to be used.

3.If the frypot temperature is below 180°F (82°C), the controller will automatically enter a warm-up cycle (often called a melt cycle). The heating elements will cycle on and off repeatedly, allowing the oil to heat gradually, without scorching. During the warm-up cycle, the heating mode light will alternately illuminate and go off as the elements cycle on and off. Within about 45 minutes, the controller will exit the warm-up cycle and the heating mode light will remain continuously illuminated.

4.When the oil temperature reaches the thermostat knob setpoint, the elements will cycle OFF and the heating mode light will go off, indicating that the fryer is ready for the cooking process to begin.

3-3

Page 13
Image 13
Frymaster MH14, BIH14 warranty Analog Controller Operating Instructions