6.2Troubleshooting

6.2.1 Controller and Heating Problems

Problem

Probable Causes

Corrective Action

 

A. Power cord is not plugged in or

A. Plug power cord in and verify

 

that circuit breaker is not

 

circuit breaker is tripped.

Controller won't

tripped.

 

activate.

B. Controller or power supply

B. Call a FAS.

 

component or interface board has

 

 

failed.

 

 

 

A. A drain safety switch prevents

 

 

the heating element from being

 

A. Drain valve is open.

energized if the drain valve is

Fryer does not heat.

 

not fully closed. Verify that the

 

 

drain valve is fully closed.

 

B. One or more other components

B. Call a FAS.

 

have failed.

 

 

 

This is normal. The default

 

 

operational mode is for the

 

 

elements to cycle on and off until

 

 

the temperature in the frypot

 

 

reaches 180ºF (82ºC). –LO–or

 

 

MLT-CYCLwill appear in the

 

 

display when in the melt-cycle

 

 

mode. The purpose of the melt-

Fryer repeatedly

 

cycle is to allow controlled melting

 

of solid shortening to prevent

cycles on and off

Fryer is in melt-cycle mode.

scorching and flash fires or damage

when first started.

 

to the element. If you are not using

 

 

solid shortening, the melt-cycle can

 

 

be bypassed. Press the “Y” yellow

 

 

key to bypass melt cycle. To

 

 

disable the melt cycle press the

 

 

check button with the controller

 

 

off. Enter 1751. To enable melt

 

 

cycle bypass, press the check

 

 

button with the controller off and

 

 

enter 1753.

 

 

This fryer is equipped with a drain

Fryer does not heat

 

safety switch that prevents the

Drain valve is open.

heating element from being

after filtering.

energized if the drain valve is not

 

 

 

fully closed. Verify that the drain

 

 

valve is fully closed.

Fryer heats until

Temperature probe or controller has

Turn fryer off and call a FAS.

high limit trips with

failed.

 

heat indicator ON.

 

 

 

6-2