Frymaster BK1814E operation manual Problem, Probable Causes, Corrective Action

Models: BK1814E

1 36
Download 36 pages 45.69 Kb
Page 32
Image 32
Manual background

Problem

Probable Causes

Fryer heats until

 

high limit trips

Contactor or controller has failed.

without heat

 

indicator ON.

 

Fryer stops heating

The high limit thermostat or

with heat indicator

contactor has failed.

ON.

 

6.2.2 Error Messages and Display Problems

Corrective Action

Call a FAS.

Call a FAS.

Problem

Probable Causes

Display is in wrong

 

temperature scale

Incorrect display option programmed.

(Fahrenheit or

 

Celsius).

 

Fryer is more than 21ºF (12ºC) above Display shows HI. setpoint.

Frypot temperature is more than

Display shows HOT. 410ºF (210ºC) or, in CE countries, 395ºF (202ºC).

Display shows LO.

Frypot temperature is more than 21ºF

(12ºC) below setpoint.

 

Corrective Action

Controller may be programmed to display in either Fahrenheit or Celsius. With the controller off, press the check button and enter 1658.

This display is normal if the fryer setpoint has been changed to a lower temperature. The display should revert to the normal four dashes when the frypot temperature cools to the setpoint. If the setpoint has not been changed, this indicates a problem with the temperature control circuitry. Turn the fryer off and call a FAS.

This in an indication of a malfunction in the temperature control circuitry, including a failure of the high limit thermostat. Shut the fryer down immediately and call a FAS.

This display is normal when the fryer is first turned on and may appear for a short while if a large batch of frozen product is added to the frypot. If the display never goes out, the fryer is not heating call a FAS.

6-3

Page 32
Image 32
Frymaster BK1814E operation manual Problem, Probable Causes, Corrective Action