Frymaster SDU90 manual DO NOT use the pump or discharge piping assembly as a handle DANGER, Danger

Models: SDU50 SDU90 BKSDU

1 13
Download 13 pages 58.77 Kb
Page 7
Image 7
3. Slowly open the drain valve. Regulate flow with the drain valve to prevent splashing.

DANGER

Before each use inspect the cover to ensure the cover gasket is present and properly placed. DO NOT use the disposal unit if this gasket is damaged or missing.

3. Slowly open the drain valve. Regulate flow with the drain valve to prevent splashing.

DO NOT use the pump or discharge piping assembly as a handle! DANGER

DO NOT OVERFILL! Do not fill the reservoir above the fill lines on the sides of the reservoir. Moving the SDU with an overfilled reservoir may result in spills and injury to personnel who come in contact with the spilled shortening.

4.Carefully withdraw the unit far enough to allow the cover to be closed. Latch the cover in the closed postion. Using the handle, carefully tip the unit back slightly for ease of handling and roll the unit to the disposal site.

Manual background WARNING

DO NOT use the pump or discharge piping assembly as a handle!

Manual background DANGER

To minimize the potential for burns, shortening/oil must always be allowed to cool below 100°F (38°C) before draining into the SDU and transporting to the disposal area. However, DO NOT allow shortening to solidify in the SDU.

The unit is designed to be moved, when properly filled, at an average walking pace on a flat surface. Care must be taken at all times when moving hot shortening or oil. Rough terrain or sudden stops and starts may cause the contents of the reservoir to spill or splash out of the reservoir, possibly causing serious injury to personnel. Always ensure that the cover is latched shut when moving the unit.

5.At the disposal site, lift the pump assembly lock pin and rotate the discharge pipe as necessary to position the discharge nipple over the opening of the disposal container. Release the lock pin to secure the pump assembly in position. Turn the pump handle clockwise. The pump should start discharging oil after a few turns. Continue turning the handle until the MSDU reservoir is empty. NOTE: The pump is NOT self-priming. If it has not been used for several days, it may have lost its prime and may need to be re-primed in accordance with Step 3 of Section 2.2.

4

Page 7
Image 7
Frymaster SDU90, BKSDU, SDU50 manual DO NOT use the pump or discharge piping assembly as a handle DANGER, Danger