...................... '.......... .............. " " ".... " 4 _1 , , _ __
TION: CONNECT TO _A::120Vi 15"AMP, BRANCH
CIRCUIT AND USEA15=AMP,TIME DELAY FUSE OR
CIRCUIT BREAKER; FAILURE TO CONNECT IN
THIS WAY CAN RESULT IN INJURY FROI_I SHOCK
OR FIRE,
Your Dust Collection System must be properly
grounded: Not all outlets areproperly grounded, tf you
are not sure that your outlet is propedy grounded.
have it checked by aqualified electrician
_WARNtNG: IF NOT PROPERLY GROUNDED,
THiS DUST COLLECTION SYSTEM CAN CAUSE
ELECTRICAL SHOCK, PARTICU LARLY WHEN USED
IN DAMP LOCATIONS;
,_.: .__ L_ WARNING: TO AVOID SHOCK OR FIRE, I!F
POWER CORD iS WORN, CUT, OR DAMAGED IN
ANY WAY, HAVE IT REPLACED IMMEO|ATELY.

GROUNDING iNSTRUCTIONS

This appliance must be grounded, tf it should malfunc-
tion or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of
electric shock. This appliance is equipped with a cord
having an equipment:grounding Conductor and ground:
ingplug. The plug must be plugged into an appropriate
outlet that is properly installed and grounded in accor-
dance with all local codes and ordinances.
_WARNING: TO MAINTAIN PROPER DUST
COLLECTION SYSTEM GROUNDING, WHENEVER
THE OUTLET YOU ARE PLANNING TO USE FOR
THIS POWER TOOL ISOFTHE TWO PRONG TYPE,
DO NOT REMOVE OR ALTER THE GROUNDING
PRONG IN ANY MANNER.

EXTENSION CORDS

This appliance is for use on a nominal 120-volt circuit,
and hasa grounded plug that looks likethe plug illustrat-
tedbelow. Atemporary adapter may be used toconnect
this plug to a 2-pole receptacle, as shown below, if a
properly grounded outlet is notavailable. The temporary
adapter should be used only until a properly grounded
outlet can be installed by a qualified electrican. The
green colored rigid ear, lug,or the like, extending from
the adapter must be connected to a permanent ground
such as a properly grounded outlet box cover. When-
ever the adapter is used. it must be held in place by a
metal screw.
WARNllNG: IMPROPERCONNECTION
OF THE EQUIPMENT GROUNDING CONDUCTOR
CAN RESULT IN ARISK OF ELECTRIC SHOCK.
CHECK WITH AQUALiFiED ELECTR]CAN OR SERV-
ICE PERSON IF YOU ARE IN DOUBT AS TO
WHETHER THE OUTLET ISPROPERLY GROU N DED.
DO NOT MODIFY THE PLUG PROVIDED WITH THE
APPLICANCE IF IT WILL NOT FIT THE OUTLET,
HAVE A PROPER OUTLET INSTALLED BY A QUALF
FlED ELECTRICIAN.
_I_-'j:_I 3-PR0 NG PLUG
It_ (J_ "_ GROUNDING PRONG
' _ _ PROPERLY
1 _1- ii _"GR0UNDED
It _ OUTLET
GROUNDING LUG
i:_;'_ij i MAKE SURE THtS IS
3-PRONG PLUG :f" L_-" ,. - CONNECTED TO A
':;'; [_ .i-:"-t_,i KNOWN GROUND
-\-.;I ,._ 2-PRONG
' - _ :" RECEPTACLE
ADAPTER
_WARNING: THE ADAPTER ILLUSTRATED IS
FOR USE ONLY IF YOU ALREADY HAVE A PROP-
ERLY GROUNDED 2-PRONG RECEPTACLE,
The useof any extension cord wiltcause some loss o!
power. Use:the following: table to determine the mini-
mumwire size (A_W,G.}extension cord. Use only 3-wire
extension cords which have 3-prong groL_nding type
For
accept the tool's
box. the wire size must be _ncreased proportionately
in order to deliver ample voltage to the sawdust collec-
tion system motor. Wire Sizes Required
Length of (American Wire Gage
Conductor 3_20YLines
tii :1"1 j:" - -'" iΒΈ: 14
0 - 25 feet No. 16
26 - 50 feet No. 14
51 - 100 feet No. 12
i,,