CF SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
3.Close the fryer drain valve and fill the frypot with water and
DANGER
4.The burner manifold pressure should be checked at this time by the local gas company or an authorized service agent. The tables below indicate the proper burner manifold pressures.
Burner Manifold Gas Pressures
Gas | Pressure | |
Natural | 3.5" W.C. | |
0.85 kPa | ||
| ||
LP | 8.25" W.C. | |
2.05 kPa | ||
|
CE Standard
Burner Manifold Gas Pressures
Gas | Pressure | |
(mbar) | ||
| ||
Natural Gas Lacq | 7,5 | |
(G20) under 20 mbar | ||
| ||
Natural Gas Gronique * | 10 | |
(G25) under 25 mbar | ||
| ||
Natural Gas Gronique | 10 | |
(G20) under 20 mbar | ||
| ||
Propane | 14.9 | |
(G31) under 37 or 50 mbar | ||
| ||
* Belgian G25 = 7,0 mbar |
| |
|
| |
|
|
5.Check the thermostat calibration or temperature programmed into the computer.
•For units equipped with thermostat controls, refer to the Thermostat Calibration instructions in Chapter 5.
•For units equipped with other types of controllers, refer to the appropriate section of the separate Frymaster Fryer Controllers User’s Manual provided with your equipment for instructions on programming and operating your controller.
2.5Converting to Another Gas Type
Your fryer is configured at the factory for either natural gas or Propane (LP) gas.
If you desire to switch from one type of gas to another, a gas conversion kit must be installed by a Factory Authorized Service Center technician.