5.For units equipped with a Computer Magic III.5 Computer:

CF SERIES GAS FRYERS

CHAPTER 3: OPERATING INSTRUCTIONS

5.For units equipped with a Computer Magic III.5 Computer:

Press the Power switch Manual background followed by the Program Mode switch Manual background. Manual background will appear in the left display.

Enter the code number Manual backgroundManual backgroundManual backgroundManual background (1653). The right display will read Manual background. The temperature is automatically set for 195°F (91°C). The fryer will attain this temperature

and remain there until the Power Manual background switch is pressed, which cancels the boil-out mode.

6.Place the fryer into operation in accordance with Section 3.1 [all except Thermostat or Solid State (Analog) Controller- See Step #2].

7.Simmer the solution for 1 hour [all except Thermostat or Solid State (Analog) Controller- See Step #2].

8.After the solution simmers for 1 hour [all except Thermostat or Solid State (Analog) Controller- See Step #2], turn the fryer off, allow the solution to cool, and then add 2 gallons (8 liters) of cold water and stir. Drain the solution into a suitable container and clean the frypot thoroughly.

Manual background WARNING

Do not drain boil-out solution into a shortening disposal unit, a built-in filtration unit, or a portable filter unit. These units are not intended for this purpose, and will be damaged by the solution.

Rinse the frypot at least twice by filling the frypot with clean water and draining. Dry the frypot thoroughly with a clean, dry towel.

Manual background DANGER

Remove all drops of water from the frypot before filling with oil or shortening.

Failure to do so will cause spattering of hot liquid when the oil is heated to cooking

temperature and may cause injury to nearby personnel.

3-5

Page 24
Image 24
Frymaster CF Series operation manual For units equipped with a Computer Magic III.5 Computer