Frymaster CF Series operation manual Drain handle in the closed position

Models: CF Series

1 50
Download 50 pages 23.7 Kb
Page 33
Image 33
Drain handle in the closed position.

CF SERIES GAS FRYERS

CHAPTER 4: FILTRATION INSTRUCTIONS

5.Remove the Power Shower and allow it to drain. Ensure the drain valve is fully closed (arrow). Turn the fryer ON and allow the oil to reach setpoint.

NOTE: Ensure the fryer drain valve is fully closed before turning the fryer on. If the drain valve is not fully closed, the controller will display an error message or a trouble light and the fryer will not operate.

Drain handle in the closed position.

Manual background WARNING

The filter pump is equipped with a manual reset switch in case the filter motor

overheats or an electrical fault occurs. If the thermal overload switch trips, turn off power to the filter system and allow the pump motor to cool 20 to 45 minutes before attempting to reset the switch.

4-8

Page 33
Image 33
Frymaster CF Series operation manual Drain handle in the closed position