Frymaster CT16 Series manual Replacing the Dual Belt Conveyor Cartridge Heater, Short screws

Models: CT16 Series

1 26
Download 26 pages 51.15 Kb
Page 8
Image 8
Short screws

7.To replace the auxiliary transformer (present only in 200V and 208V units), hold the replacement next to the failed transformer and, one at a time, disconnect the wires from the failed transformer and connect them to the replacement. When all wiring has been transferred, remove the screws and nuts that secure the transformer to the back wall of the motor compartment and install the replacement.

Short screws

8. Reverse the steps performed to reassemble unit.

Replacing the Dual Belt Conveyor Cartridge Heater

1.Turn off and unplug the unit.

2.Pull the bun compression knobs off their shafts.

3.Remove the screws in the edge of the component housing cover.

4.Disconnect the heater leads. Remove the hex-head screws securing the heater in place and remove the heater (see illustration on Page 1-6).

5.Reverse steps 1-4 to reassemble the unit.

Replacing the Transformer or Relays

1.Turn off and unplug the unit.

2.Pull the bun compression knobs from their shafts.

3.Remove the screws in the edge of the component housing cover.

4.Hold the replacement component next to the component to be replaced and, one at a time, disconnect the wires from the failed component and connect them to the replacement component.

5.Remove the screws and/or nuts securing the failed component to the component housing and install the replacement.

6.Reverse steps 1-3 to reassemble the unit.

1-6

Page 8
Image 8
Frymaster CT16 Series Replacing the Dual Belt Conveyor Cartridge Heater, Replacing the Transformer or Relays, Short screws