 Operation Tips

Manual backgroundManual background Operation Tips

Operation and Performance

*Heating Performance

Manual background This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating perfomance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

Manual background Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.

Instructions relating to heating (*) are applicable only to "HEAT & COOL TYPE".

Temperature and Humidity Range

*Microcomputer-controlled Automatic Defrosting

Manual background When using the Heating mode under conditions of low outdoor air temperature high humidity, frost may form on the outdoor unit, resulting in reduced operating performance.

Manual background In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Automatic Defrosting function. If frost forms, the air conditioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7 to 12 minutes).

During Automatic Defrosting operation, the OPERATION Indicator Lamp will flash.

*Trouble alarming performance

During operation, when there is any trouble,

the operation indicator lamp will flash with different times.

Cooling

Indoor

outdoor

 

Rated

Maximum

Minimum

DB C

27

32

18

WB C

19

23

14

DB C

35

43

10

WB C

24

26

6

DB C

20

27

15

Heating Indoor outdoor

WB C

14.5

--

--

DB C

7

24

-7

WB C

6

18

--

Manual background If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

Manual background Do not use this unit for any other purposes except for the Cooling, Heating, Dehumidifying, and air- circulation of rooms in ordinary dwellings.

Manual background The wiring method should be in line with the local wiring standand.

Manual background The waste battery should be disposed properly.

Manual background If the fuse on PC board is broken, please change it with the type T 3.15A/250VAC. Manual background The indoor unit installation height is at least 2.5m.