Frymaster HCFU-42CF03, HCFU-42HF03 installation manual Installation of Indoor Unit

Models: HCFU-42HF03 HCFU-42CF03

1 29
Download 29 pages 32.4 Kb
Page 15
Image 15
INDOOR UNIT

Manual backgroundManual background Installation of Indoor Unit

(1)Install the indoor unit level on a strong wall which is not subject to vibration.

(2)The inlet and outlet ports should not be obstructed : the air should be able to blow all over the room.

(3)Do not install the unit where it will be exposed to direct sunlight ,

(4)Install the unit where connection to the outdoor unit is easy.

(5)Install the unit where the drain pipe can be easily installed.

(6)Take servicing , etc.into consideration and leave the spaces shown in (Fig.1 or 2) . Also install the unit where the filter can be removed .

Fig. 1

Ceiling

INDOOR UNIT

3"(80mm)

6"(150mm)

over

over

0.4"(10mm) Manual backgroundManual background over

FOR HALF CONCEALED INSTALLATION

Ceiling panel

Fig. 2

INDOOR UNIT

3"(80mm)

 

 

6"(150mm)

over

 

 

over

 

 

 

 

Ceiling panel

 

 

 

 

 

 

 

 

 

 

 

 

 

0.4"(10mm) Manual backgroundManual background over