ELECTRICAL WIRING

B.For strand wiringA. Solid wire Installation of Indoor Unit

ELECTRICAL WIRING

HOW TO CONNECT WIRING TO THE TERMINALS A.For solid core wiring (or F-cable)

(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 15/16"(25mm) of expose the solid wire.

(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board. (3)Using pliers,bend the solid wire to form a loop suitable for the terminal screw.

B.For strand wiring

(1)Cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 3/8"(10mm) of expose the solid wire.

(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.

Fig. 14

A. Solid wire

B. Strand wire

Strip 15/16"(25mm)

Loop

Insulation

Strip 15/16"(25mm)B. Strand wire

Round terminal

Screw with special washer

Round terminal

Terminal

Wireboard

Wire

Screw with special washer

Round terminal

HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP

After passing the connection cord and power cable through the insulation tube, fasten it with the cord clamp, as shown in Fig.15