Frymaster M2000 Programming for Dedicated Product Operation, second duty alarm will sound

Models: M2000

1 30
Download 30 pages 29.66 Kb
Page 14
Image 14
second duty alarm will sound.

Programming for Dedicated Product Operation

Sets Cooktime.

Sets Quality time.

Sets product cooking temperature or setpoint.

second duty alarm will sound.

13.Use numbered product keys to enter a time if required. M :00 is the default setting.

14.Follow step 10 to toggle between automatic and manual alarm canceling.

15.Press Manual background. Remove appears in left display. M 3:10 appears in the right. This sets cook time for the product selected. Use numbered keys to change time as required. 3:10 is the default cook time for french fries.

16.Press Manual background to toggle between automatic and manual alarm canceling.

17.Press Manual background. QUAL appears in left display. M 7:00 in the right. This is the default quality hold time for french fries. Use numbered product keys to change time as required. Entering zero will disable the quality timer.

18.Press Manual background to toggle between automatic and manual alarm canceling.

19.Press Manual background. Set-Tempappears in the left display. 335F (168°C) appears in the right. This is the default setpoint for french fries. Use numbered product keys to change if required.

20.Repeat steps 7-19 for additional items.

21.With the last programmed menu item displayed on the computer,

press Manual background to lock in menu item and exit programming.

4-2

Page 14
Image 14
Frymaster M2000 operation manual Programming for Dedicated Product Operation, second duty alarm will sound