Programming Multi-Product Operation

Programming Multi-Product Operation

Programming Multi-Item Vat

Stores menu item in product button.

Sets cooking temperature.

Sets duty time.

1.Computer displays OFF (Computer must be off to enter programming mode.)

2.Press Programming Multi-Item Vat

3.Code appears in left display

 

1

6

5

0

4. Press

 

 

 

(1650) with product keys.

 

 

 

 

 

 

5.FR FRIES appears in the left display. Right display is blank.

6.The LED will illuminate in product button 1, the default product button for fries.

7. Press

2

to move to the next menu item.

8.Filet appears in the left display.

9.Choose and press the product button to store the cooking cycle. The LED in the chosen product button will illuminate. The right display is blank.

10.Press Manual background on the right side of the split pot fryer and YES appears in the display above the cook channel button. This sets the setpoint to the temperature for filets.

11.Press Manual background. Duty 1 appears in the left display. M :00 in the right. This sets the seconds into the cook cycle that a duty alarm sounds.

12.Press Manual background to toggle between automatic and manual alarm canceling. The left display will alternate between M :00 and A

:00 as Manual background is pressed. Manual alarm canceling is the default setting.

13.Press Manual background. Duty 2 appears in the left display. M :00 appears in the right. This sets the time into the cook cycle in which a second duty alarm will sound.