![Programming for Dedicated Product Operation](/images/new-backgrounds/59902/5990225x1.webp)
Programming for Dedicated Product Operation
Example:
Programming
Dedicated Vats
Stores menu item in product button.
Sets setpoint for fries.
Sets duty time.
Sets alarm cancellation choice.
Sets second duty alarm.
1.Computer displays OFF (Computer must be off to enter program mode.)
2.Press
3.Code appears in left display
| 1 | 6 | 5 | 0 |
4. Press |
|
|
| (1650) with product keys. |
|
|
| ||
|
|
|
5.FR FRIES appears in the left display. Right display is blank.
6.The LED will illuminate in product button 1, the default product button for fries.
7. Press | 2 |
to advance to another menu item if required. In |
this example the computer is dedicated to french fries.
8.Press on right side of computer. YES appears above both
buttons on a full pot; it appears only above on a split pot. This step sets the vat setpoint to 335°F (168°C), the setpoint for french fries.
9.Press on right side of computer. YES appears in display above button. This step sets the right vat setpoint on a splitpot to 335°F (168°C).
10.Press . Duty 1 appears in the left display. M :30 in the right. This sets the seconds into the cook cycle that a duty alarm sounds. M :30 is the default setting and should be used.
11.Press to toggle between automatic and manual alarm canceling. The left display will alternate between M :30 and A
:30 as is pressed. Manual alarm canceling is the default setting.
12.Press . Duty 2 appears in the left display. M :00 appears in the right. This sets the time into the cook cycle in which a