DANGER

Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. A restraint kit is provided with the fryer. If the restraint kit is missing contact your local Frymaster Factory Authorized Service Center (FASC) for part number 826-0900.

DANGER

Prior to movement, testing, maintenance and any repair on your Frymaster fryer, disconnect all electrical power from the fryer.

ELECTRICAL POWER SPECIFICATIONS

Three (3) Phase Requirements

 

 

 

WIRE

MINIMUM SIZE

AMPS PER LEG

kW

VOLTAGE

PHASE

SERVICE

AWG

mm2

L1

L2

L3

17

208

3

3

6

16

48

48

48

17

240

3

3

6

16

41

41

41

17

480

3

3

6

16

21

21

21

17

220/380

3

4

6

16

26

26

26

17

240/415

3

4

6

16

24

24

24

17

230/400

3

4

6

16

25

25

25

21

208

3

3

4

25

57

57

57

21

240

3

3

4

25

50

50

50

21

480

3

3

6

16

25

25

25

21

220/380

3

4

6

16

N/A

N/A

N/A

21

240/415

3

4

6

16

29

29

29

21

230/400

3

4

6

16

27

27

27