HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
3.5Gas Specifications
CE ONLY (Altitudes of 2000 feet or less)
MODEL | INPUT | GAS | ORIFICE | ORIFICE | QTY | EQUIPMENT | ||
PRESSURE | ||||||||
(kW) | TYPE | (MM) | PART NO. | |||||
|
| MBAR | INCH W.C. | |||||
|
|
|
|
|
| |||
D20G | 15,0 | G20 | 2,40 | 2 | 10,0 | 4,0 | ||
G25 | 2,40 | 2 | 15,0 | 6,0 | ||||
|
| G31 | 1,51 | 2 | 27,0 | 10,8 | ||
|
| G20 | 2,40 | 4 | 10,0 | 4,0 | ||
D50G | 30,0 | G25 | 2,40 | 4 | 15,0 | 6,0 | ||
|
| G31 | 1,51 | 4 | 27,0 | 10,8 | ||
|
| G20 | 2,40 | 5 | 10,0 | 4,0 | ||
D60G | 37,5 | G25 | 2,40 | 5 | 15,0 | 6,0 | ||
|
| G31 | 1,51 | 5 | 27,0 | 10,8 | ||
|
| G20 | 2,40 | 5 | 10,0 | 4,0 | ||
D80G | 37,5 | G25 | 2,40 | 5 | 15,0 | 6,0 | ||
|
| G31 | 1,51 | 5 | 27,0 | 10,8 |
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.
(Pilot Flame Adjustment: Turn the pilot adjustment screw
3.6 Gas Conversion Procedures
DANGER
This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires the installation of specific
Switching to a different type of gas without installing the proper conversion components may result in fire. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.6 of this manual.
Contact factory with the following information when performing conversions:
• | Fryer Serial Number | • | Gas Type |
• | Fryer Model Number | • | Operating Altitude |
Conversions can only be executed by qualified,
Pilot pressure adjustment | Pressure flow adjustment |
(remove cover screw to | (remove cover screw to |
access) | access) |
| Regulator Vent |
Pilot gas supply | ON/OFF |
connection. | |
|
Typical