HIGH EFFICIENCY DECATHLON (HD) SERIES GAS FRYERS

CHAPTER 5: CONTROLLER OPERATING INSTRUCTIONS

5.1 Operating Instructions: Electronic Thermostat Controller (cont.)

FRYER POWER SWITCH – This switch turns the fryer on and off. When the power switch is in the "ON" position, the indicator light will be lit when calling for heat.

BOIL-OUT SWITCH (Optional) – When the boil-out switch is "ON", it will bypass the electronic thermostat melt-cycle, and allow the water temperature to reach approximately 196°F (91°C).

DRAIN RESET SWITCH (Optional) – Resets drain safety switch after draining the fryer. Drain valve must be closed completely before resetting switch.

MANUAL FILTER POWER SWITCH (if equipped with filter system) – Controls power to the filter pump in the event the primary system fails. Fryer Power Switch should be in "OFF" position

when in use.

FILTER RESET BREAKER (7 Amp Circuit Breaker- 120VAC or 5 Amp Circuit Breaker- 230VAC) – the breaker is inline between the filter switch and the pump. Ensure filter power is off prior to resetting or replacing.

5 AMP (115VAC) or 2 AMP (230VAC) FUSE – each fryer circuit is protected by a 5 amp (115VAC) or 2 amp (230VAC) fuse located under the control panel.

5.2 Electronic Thermostat Controller/Computer

Fryer Power Switch: controls power to each individual fryer, both in Electronic Thermostat or back-up mode.

Main Power Switch (optional): connects/disconnects primary power; double-lighted with center position "OFF". This switch controls two Electronic Thermostat controllers/Compu-Fry or remote computers and/or two back-up thermostats (optional).

POWER

O

F

F

BOIL OUT

O

F

F

O N

O N

B ON OFF ON

 

 

C

 

 

O

A

 

 

T

 

M

C

 

 

OR

P

K

 

 

M

U

 

 

T

 

U

 

 

 

 

T

P MAIN POWER

 

 

E

 

 

 

 

 

R

POWER

O

F

F

BOIL OUT

O

F

F

O N

O N

B ON OFF ON

 

 

C

 

 

O

A

 

 

T

 

M

C

 

 

OR

K

 

 

M

P

U

 

 

T

 

U

 

 

 

 

T

P MAIN POWER

 

 

E

 

 

 

 

 

R

 

 

 

 

 

High-Limit Reset Switch: located under each individual control panel. This switch must be manually reset if fryer exceeds high-limit setpoint.

Filter Reset Switch [7 Amp (115VAC) or 5 Amp (230VAC) Circuit Breaker]: this switch is inline between the filter pump and incoming line voltage. Ensure power is "OFF" before resetting or replacing.

Boil-Out Switch: operates only in "Electronic Thermostat" mode. When "ON", this switch bypasses the Electronic Thermostat melt-cycle and allows the water temperature to reach 196°F (91°C).

5–2

Page 29
Image 29
Frymaster SCFHD operation manual Electronic Thermostat Controller/Computer, When in use