AUTO Restart

OPERATING TIPS

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

AUTO Restart

In Event of Power Interruption

Should the power supply to the air conditioner be inter- rupted by a power failure, the air conditioner will restart automatically in the previously selected mode once the power is restored.

Should a power failure occur during TIMER operation, the timer will be reset and the unit will begin (or stop) operating under the new timer setting. In this event, the TIMER indicator lamp (yellow) will flash (see page 4).

Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the power supply, reconnect it, and then use the remote control unit to resume operation.

Temperature and Humidity Range

COOLING/DRY MODE

 

 

 

 

 

 

 

 

Outdoor

Outdoor

 

Indoor

 

 

 

 

 

 

 

Unit

Temperature

Temperature

 

Humidity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

About 80 % or less

COOLING MODELS

 

AOU18CXQ

About 32 to 110 °F

 

 

If the unit is used for long pe-

 

AOU24CXQ

 

 

riods under high-humidity

 

 

 

 

 

 

 

 

 

About 65 to 90 °F

 

conditions, condensation

 

 

 

 

 

may form on the surface of

HEAT & COOL

 

 

 

 

 

 

 

 

 

 

AOU18RXQ

About 32 to 110 °F

 

 

the indoor unit, and drip onto

MODELS

 

 

 

 

AOU24RXQ

 

 

the floor or other objects un-

(Reverse Cycle)

 

 

 

 

 

 

 

 

 

derneath.

 

 

 

 

 

 

*HEATING MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor

Outdoor

Indoor

 

 

 

 

Unit

Temperature

Temperature

 

 

 

 

 

 

 

 

 

HEAT & COOL

 

AOU18RXQ

About 32 to 75 °F

About 86 °F or less

 

 

MODELS

 

 

 

 

AOU24RXQ

 

 

(Reverse Cycle)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in ordinary dwellings.