Features

Replacing the RAID Controller

 

 

 

 

Jum-

Type

Description

 

pers

 

 

 

 

 

 

 

J9

I 2C connector

3-pin connector

 

 

 

Used for enclosure management.

 

 

 

Reserved for internal use

 

 

 

 

 

J10

Write Pending Indication

2-pin connector

 

 

LED

Connector for enclosure LED.

 

 

 

When lit, it indicates the onboard cache

 

 

 

contains data and a write from the cache

 

 

 

to the hard drives is pending. Optional.

 

 

 

 

 

J11

x4 SAS ports 0 - 3

SFF 8484 x4 connector for connection to

 

 

 

physical drives and expanders.

 

 

 

 

 

J12

GND connector

Reserved for internal use

 

 

 

 

 

J13

GND connector

Reserved for internal use

 

 

 

 

 

J14

GND connector

Reserved for internal use

 

 

 

 

 

J15

I 2C connector

4-pin connector

 

 

 

Used for enclosure management.

 

 

 

Reserved for internal use

 

 

 

 

 

J18

SMBUS header for

3-pin header

 

 

enclosure management

Used for enclosure management.

 

 

 

Reserved for internal use

 

 

 

 

 

Table 2: Jumpers and Connectors

 

 

Step 4 Remove the RAID SAS controller from the Mainboard

Remove the PCI card hold down latches that fix the RAID SAS controller to the computer chassis.

Remove the RAID SAS controller from the PCI Express slot on the motherboard (see your mainboard guide for information about the PCI Express slot).