3.3 Replacing Consumable

2) Pull the Pick roller unit to the fixture‘s side.The Pick roller unit is removed downwards.4. Attach a new Pick roller unit to the scanner.Attatch a new Pick roller unit to the scanner in reverse order of removing.

1)Set the Pick roller unit inserting an end of shaft into the shaft hole correctly as shown in the following photos.

3

MAINTENANCE

ATTENTION

Make sure that the end of the Pick roller unit shaft is correctly inserted in the shaft hole. Otherwise the ADF will not be closed completely.

2) Lock the fixture in the original place to fix the Pick roller unit.

fi-5015C Image Scanner Operator’s Guide

 

51