TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

WARNING!

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical

breaker, and consult authorized service personnel.

 

Merely turning off the unit’s power switch will not completely disconnect the unit from the power

 

source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

 

Symptom

 

 

Problem

See

 

 

 

Page

 

 

 

 

 

NORMAL

Doesn’t operate immedi-

● If the unit is stopped and then immediately started again, the com-

 

FUNCTION

ately:

 

pressor will not operate for about 3 minutes, in order to prevent

 

 

 

 

fuse blowouts.

 

 

● Whenever the electrical breaker is turned off then on again, the

 

 

 

 

 

 

protection circuit will operate for about 3 minutes, preventing unit

 

 

 

 

operation during that period.

 

 

Noise is heard:

● During operation and immediately after stopping the unit, the

 

 

 

 

sound of water flowing in the air conditioner’s piping may be heard.

 

 

 

 

Also, noise may be particularly noticeable for about 2 to 3 minutes

 

 

 

after starting operation (sound of coolant flowing).

 

 

● During operation, a slight squeaking sound may be heard. This is

 

 

 

 

the result of minute expansion and contraction of the front panel

 

 

 

 

due to temperature changes.

 

 

 

*●

During Heating operation, a sizzling sound may be heard occasion-

14

 

 

 

ally. This sound is produced by the Automatic Defrosting operation

 

 

 

 

 

Smells:

● Some smell may be emitted from the indoor unit. This smell is the

 

 

 

 

result of room smells (furniture, tobacco, etc.) which have been

 

 

 

taken into the indoor unit.

 

 

Mist or steam are

● During Cooling or Dry operation, a thin mist may be seen emit-

 

 

emitted:

 

ted from the indoor unit. This results from the sudden Cooling of

 

 

 

room air by the air emitted from the indoor unit, resulting in con-

 

 

 

 

 

 

 

densation and misting.

 

 

 

*● During Heating operation, the outdoor unit’s fan may stop, and

 

 

 

 

steam may be seen rising from the unit. This is due to the Auto-

14

 

 

 

matic Defrosting operation.

 

 

Airflow is weak or stops:

*● When Heating operation is started, fan speed is temporarily very

 

 

 

 

low, to allow internal parts to warm up.

 

 

 

*●

During Heating operation, if the room temperature rises above

 

 

 

the thermostat setting, the outdoor unit will stop, and the indoor

 

 

 

 

 

 

 

unit will operate at very low fan speed. If you wish to warm the

 

 

 

 

room further, set the thermostat to a higher setting.

 

 

 

*● During Heating operation, the unit will temporarily stop opera-

 

 

 

 

tion (between 4 and 15 minutes) as the Automatic Defrosting

14

 

 

 

mode operates. During the Automatic Defrosting operation,

 

 

 

 

 

 

 

 

will be shown on the remote controller display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The fan may operate at very low speed during Dry operation or

 

 

 

when the unit is monitoring the room’s temperature.

 

 

 

 

 

 

During QUIET operation, the fan will operate at very low

 

 

 

speed.

 

 

 

 

 

 

In the monitor AUTO operation, the fan will operate at very low

 

 

 

speed.

 

 

 

 

In case of Multi-type unit, if multiple units are operated in differ- ent operation modes as shown below, the units operated after-

 

ward will stop and the OPERATION indicator lamp (green) will

16

 

flash,

 

will be shown on the remote controller display.

 

 

 

 

 

 

 

Heating mode and cooling mode (or dry mode)

 

 

Heating mode and fan mode

 

Water is produced from

*● During Heating operation, water may be produced from the out-

14

the outdoor unit:

door unit due to the Automatic Defrosting operation.

 

The ECONOMY Indicator flashes

● Clean the filter. Afterwards, turn the ECONOMY Indicator off.

12

thermo sensor display

● The room temperature sensor may be malfunctioning. Please con-

 

on the remote controller

sult authorized service personnel.

is flashing:

 

 

 

 

En-13

9374379392-04_OM.indb 13

9/6/2010 10:36:32 AM

Page 14
Image 14
Fujitsu Halcyon Air Conditioner, 9374379392-04 manual Troubleshooting, Symptom Problem, Normal, Function