Chapter 1 System Overview 1-3
The environmental requirements listed in TABLE1-2 reflect the test results of theserver. The optimum conditions indicate the recommended operating environment.Operating the server for extended periods at or near the operating range limits orinstalling the server in an environment whereit remains at or near the non-operatingrange limits could possibly increase the failure rate of hardwarecomponentssignificantly. In order to minimize the occurrence of system failure due tocomponent failure, set temperature and humidity in the optimal ranges.
Redundant cooling • Two 172-mm fans (One fan is
redundant)
• Two 60-mm fans (One fan is
redundant)
Four 172-mm fans per server
Twofans are redundant
Internal drives 1 CD-RW/DVD-RWdrive unit,
2 harddisk drives,
1 tape drive unit (optional)
1 CD-RW/DVD-RWdrive unit,
4 harddisk drives,
1 tape drive unit (optional)
Domains 2 4
Architecture Platform group:sun4u
Platform name: SUNW,SPARC-Enterprise
Rackmountable Equipment rack
Server dimensions
(width x depth x height)
444 x 810 x 263 mm (6 rack units)
17.5 x 31.9 x 10.3 inches
444 x 810 x 440 mm (10 rack units)
17.5 x 31.9 x17.3 inches
Weight 185 lb. (84 kg) 275 lb. (125 kg)
RFID tag*PASSIVEUHF EPC Class 1 GEN2
Financial Services TechnicalConsortium (FSTC) compliant EPC
pre-programmed
Frequency:860-960 MHz
Read range: 1.8m (6ft) fixedreader/ 90cm (3ft) hand-held
* ARadio Frequency Identification(RFID) tag is used for asset identification. The RFID tag provides identification information via short
distance radio waves to an RFID reader or sensor. The tag contains a unique Electronic Product Code (EPC) serial number and a 2-D
Data Matrix code.
† Frequency is defined by the government of each country.
‡ Read range is affected by tag orientation, sensitivity, and reader performance.
TABLE1-1 ServerFeatures (Continued)
Features M4000Server M5000Server