Chapter 1 System Overview 1-19
TABLE1-6 lists the power supply features and some specifications. For additional
specifications,refer to the SPARC Enterprise M4000/M5000 Servers Site Planning Guide.
CPU Types and Server Maximum PowerConsumptionThis section describes the CPU types and the maximum power consumption of the
server.
There are four types of CPU. The power specifications of the M4000/M5000 servers
vary depending on the CPU type and the system configuration.
TABLE1-7 and TABLE 1-8 list the specifications of maximum power consumption,
apparent power,and heat dissipation by the type of CPU. The figures represent the
system configuration described below the table, in which every CPU Modules
(CPUM) is mounted with the same CPU.
Note – Valuesin TABLE 1-7 and TABLE 1-8 are rounded to the nearest whole number.
TABLE1-6 Midrange Servers Electrical Specifications
M4000Server M5000Server
Numberof power
cords 2 (1 power cordper power supply unit) 4 (1 power cord per power supply unit)
Redundancy 1 + 1 redundant
Second power supply is redundant at 200 VAC
2 + 2 redundant
Second and fourth power supplies are
redundantat 200 VAC
Inputvoltage 100–127VAC
200–240 VAC
100–127 VAC
200–240 VAC
Maximumcurrent 24.0A at 100–127 VAC(12A/cord)
12.0A at 200–240 VAC(12A/cord)
48A at 100–127 VAC(12A/cord)
24A at 200–240 VAC(12A/cord)
Frequency 50–60 Hz 50–60 Hz
Powerfactor 0.98 0.98