Chapter 3 Installing the Server 3-7
See SectionA.1, “M4000 Server Views” on page A-1 for the location of the XSCF Unit
on the SPARCEnterprise M4000 server.
3.3.1 Connecting the Console
This section explains how to physically connect and configure the console.
1. Connect the administrative console to the serial port using the serial cable that
shipped with the server.
2. Configure the settings on the administrative console.
The console should have the following settings:
Baud rate: 9600 bps
Data length: 8 bit
Parity: None
Stop: 1 bit
Flow control: None
Delay: Except for 0
3. Set the key on the operator panel to the Service position.
The Service position is indicated by an icon that looks like a wrench, the Locked
position is indicated by an icon that looks like a lock (FIGURE3-3).
5LAN 0 (Ethernet#0)
6UPC#1
7UPC#0
LocationNumber Component