7.2Sense Data Analysis

7.2.1Error information indicated with sense data

Subsection 7.2.2 onwards explain troubleshooting using sense data.

Table 7.1 lists the definition of sense data. For details of sense data, refer to the SCSI Logical Interface Specifications.

 

 

 

 

Table 7.1 Definition of sense data

 

 

 

 

 

 

Sense data

 

 

 

 

 

 

 

Sense

Sense

 

Sub

Definition

key

Code

 

Sense

 

 

 

 

Code

 

 

 

 

 

 

00

00

 

00

Operation was normal.

 

 

 

 

 

3

0C

 

03

A write to a disk terminated abnormally.

 

 

 

 

 

4

32

 

01

Failed to update the defect list due to a disk medium write error, etc.

 

40

 

xx

An error occurred in power-on self-diagnosis.

 

44

 

xx

A hardware error occurred inside IDD.

 

C4

 

xx

A drive error occurred.

 

 

 

 

 

1

1x

 

xx

A disk read error occurred.

3

1x

 

xx

A disk read error occurred.

 

 

 

 

 

E

1D

 

00

Data discrepancy found by VERIFY command byte check.

 

 

 

 

 

5

2x

 

xx

An SCSI error, such as an invalid operation code, occurred.

 

3D

 

00

The Reserve bit of the IDENTIFY message was set to 1.

 

90

 

00

The RESERVE or RELEASE command cannot be executed because

 

 

 

 

the SCSI ID of the INIT was not posted in the SELECTION phase.

B

47

 

xx

A parity error occurred in the SCSI data bus.

B

49

 

00

An unmounted or inappropriate message was received.

B

4D

 

xx

Before completion of a command, a command with the same tag

 

 

 

 

number was issued.

B

4E

 

00

An overlap command was issued.

 

 

 

 

 