Fujitsu MAS3735NC/NP, MAS3184NC/NP, MAS3367NC/NP Alternate block allocation by Format Unit command

Models: MAS3367NC/NP MAS3184NC/NP MAS3735NC/NP

1 130
Download 130 pages 40.65 Kb
Page 47
Image 47

: n represents a logical data block number

: Defective sector

: Unused spare sector

Figure 3.7 Alternate block allocation by FORMAT UNIT command

During FORMAT UNIT command, alternate block allocation is conducted in following cases:

1)Unrecovered write offtrack condition during a media write

2)Uncorrectable Data Error during a media read (certification) *1

If above errors are detected during FORMAT UNIT command, the IDD allocates the alternate block(s) to the defective data blocks. Reassign procedure itself is the same as one in REASSIGN BLOCKS command.

*1. Certification is permitted when DCRT flag is cleared (DCRT flag=0) in FORMAT UNIT command.

The IDD checks all initialized logical data blocks by reading them out after the above alternate block allocation is made to initialize (format) the disk.

C141-E185

3-13

Page 47