6.3Operation Check

6.3.1Initial seek operation check

If an error is detected during initialization by the initial seek operation check routine at power-on, the spindle motor of the disk drive stops, and then the disk drive becomes unusable.

For an explanation of the operation check before the initial seek, refer to the Section 5.6.

6.3.2Operation test

While the host computer is processing data, the HDD monitors disk drive operation including data processing, command processing, and seek operations. If the HDD detects an error, the HDD posts the error to the initiator. The initiator then posts the error to the user.

The user may detect an intermittent or nonfatal error such as abnormal noise, abnormal odor, or very slow operation.

An error posted in an operation test must be investigated. Replace the disk drive to see whether the error was caused by the disk drive.

Often, errors posted in an operation test may be caused by the host system. Possible causes include insufficient power capacity, loose cable connection, insufficient timing or insufficient mechanical play, and problems related to other systems.

If an operation error is detected by the error detection circuit of the disk drive, an interrupt occurs. The interrupt is posted to the MCU on the PCA. The MCU stops the currently processed command, and causes the CHECK CONDITION status to post the error to the initiator.

When receiving the CHECK CONDITION status, the initiator issues a REQUEST SENSE command to collect detailed information about the error. The initiator then issues a REZERO UNIT command to return the read/write head to track 00. In normal processing, the HDD itself or initiator determines how to handle the error (processing retry or stop).

To analyze the error posted in the operation test, reconstruct the conditions in which the error occurred. Then, start troubleshooting the whole host system by replacing the disk drive.

6.3.3Diagnostic test

The diagnostic test is executed to find a faulty subassembly in a faulty disk drive, or to check disk drive performance. This test is usually a combination of specific disk drive functions or group of functions. This test may be executed using a different host computers or test equipment and away from the environment where the error first occurred.

To analyze the error posted in the diagnostic test, reconstruct the conditions in which the error occurred. Then, look for a possibly faulty subassembly or part of the disk drive.

The procedures to be used in this test depend largely on the type of test equipment used, and are not covered by this manual.

C141-E226

6-11

Page 107
Image 107
Fujitsu MAW3147NC/NP, MAW3300NC/NP manual Operation Check Initial seek operation check, Operation test, Diagnostic test

MAW3147NC/NP, MAW3073NC/NP, MAW3300NC/NP specifications

Fujitsu has established itself as a key player in the world of hard disk drives, and their MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP models showcase exemplary engineering and innovative technology. These drives are designed primarily for enterprise applications, providing robust performance, reliability, and data integrity in demanding environments.

One of the standout features of the Fujitsu MAW series is its high storage capacity. The MAW3073NC/NP model comes with a generous 73 GB capacity, while the MAW3300NC/NP boasts 300 GB, and the MAW3147NC/NP offers 147 GB of storage. This range makes them suitable for various applications, from databases to data-intensive software.

The drives utilize the latest Serial Attached SCSI (SAS) interface, which ensures high speed and efficiency in data transfer. SAS technology provides better bandwidth and performance compared to older parallel SCSI interfaces, enabling faster access to data and improved overall system responsiveness. With rotational speeds of 10,000 RPM, these drives further enhance performance, enabling faster read and write times, which is critical for enterprise applications that require quick data retrieval.

Another noteworthy characteristic of the Fujitsu MAW series is their advanced error recovery and data integrity features. The drives are equipped with sophisticated error correction mechanisms and management systems that help maintain data integrity, ensuring that the data remains intact even in the event of power loss or system failure. This reliability is paramount for enterprise environments where data loss can result in significant operational disruptions.

In terms of physical design, these drives are built to endure the rigors of high-demand environments. They feature a robust construction that allows for efficient heat dissipation, minimizing the risks associated with overheating. Additionally, their form factor is designed for easy integration into various server and storage systems, making them versatile solutions for IT infrastructure.

Fujitsu's commitment to sustainability is also evident in the MAW series with their energy-efficient operation and reduced power consumption, contributing to decreased overall operational costs. With a combination of high performance, reliability, and sustainability, the Fujitsu MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP hard drives stand out as formidable choices for organizations looking to optimize their data storage solutions. They embody the cutting-edge technology and quality that Fujitsu is known for in the enterprise storage market.