A.1 Setting Terminals (on NP model only)

 

 

 

Table A.1

CN2 setting terminal (on NP model drives only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting item

 

 

 

 

 

Pin pair

 

 

 

 

 

 

 

Setting contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 - 2

 

3 - 4

5 - 6

7 - 8

 

9 - 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI ID

 

Open

 

 

Open

Open

 

(Open)

 

 

 

SCSI ID #0

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Open

 

(Open)

 

 

 

SCSI ID #1

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Open

 

(Open)

 

 

 

SCSI ID #2

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Open

 

(Open)

 

 

 

SCSI ID #3

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Open

Short

 

(Open)

 

 

 

SCSI ID #4

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Short

 

(Open)

 

 

 

SCSI ID #5

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Short

 

(Open)

 

 

 

SCSI ID #6

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Short

 

(Open)

 

 

 

SCSI ID #7

(Common to 8-bit and 16-bit SCSI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Open

Open

 

Short

 

 

 

SCSI ID #8

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Open

 

Short

 

 

 

SCSI ID #9

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Open

 

Short

 

 

 

SCSI ID #10

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Open

 

Short

 

 

 

SCSI ID #11

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Open

Short

 

Short

 

 

 

SCSI ID #12

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Open

Short

 

Short

 

 

 

SCSI ID #13

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

 

Short

Short

 

Short

 

 

 

SCSI ID #14

(16-bit SCSI only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

Short

Short

 

Short

 

 

 

SCSI ID #15

(16-bit SCSI only) (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write protect

 

 

 

 

 

 

 

 

 

 

 

 

Open

Write operation is enabled. (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

Write operation is disabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting item

 

 

 

 

 

Pin pair

 

 

 

 

Setting contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 - 12

13 - 14

15 - 16

23 - 24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor start mode

 

 

 

Open

 

 

 

 

 

 

 

 

 

 

Started by the START/STOP command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

 

 

 

 

 

 

 

 

Started by turning the power supply on (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Force Narrow

 

 

 

 

 

 

Open

 

 

 

 

 

 

Width of 16-bit bus (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

 

 

 

 

Width of 8-bit bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Force Single Ended

 

 

 

 

 

 

 

 

Open

 

 

 

Follows DIFFSNS signal level on SCSI bus (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

 

 

 

Single-Ended mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminating power supply

 

 

 

 

 

 

 

 

 

Open

Does not supply terminating resistor power to SCSI BUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short

Supply terminating resistor power to SCSI BUS (*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Setting at factory shipment

Note:

See the description of Section 5.3 for details of the setting requirements and notes.

A-2

C141-E226

Page 118
Image 118
Fujitsu MAW3073NC/NP, MAW3300NC/NP, MAW3147NC/NP manual Scsi ID

MAW3147NC/NP, MAW3073NC/NP, MAW3300NC/NP specifications

Fujitsu has established itself as a key player in the world of hard disk drives, and their MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP models showcase exemplary engineering and innovative technology. These drives are designed primarily for enterprise applications, providing robust performance, reliability, and data integrity in demanding environments.

One of the standout features of the Fujitsu MAW series is its high storage capacity. The MAW3073NC/NP model comes with a generous 73 GB capacity, while the MAW3300NC/NP boasts 300 GB, and the MAW3147NC/NP offers 147 GB of storage. This range makes them suitable for various applications, from databases to data-intensive software.

The drives utilize the latest Serial Attached SCSI (SAS) interface, which ensures high speed and efficiency in data transfer. SAS technology provides better bandwidth and performance compared to older parallel SCSI interfaces, enabling faster access to data and improved overall system responsiveness. With rotational speeds of 10,000 RPM, these drives further enhance performance, enabling faster read and write times, which is critical for enterprise applications that require quick data retrieval.

Another noteworthy characteristic of the Fujitsu MAW series is their advanced error recovery and data integrity features. The drives are equipped with sophisticated error correction mechanisms and management systems that help maintain data integrity, ensuring that the data remains intact even in the event of power loss or system failure. This reliability is paramount for enterprise environments where data loss can result in significant operational disruptions.

In terms of physical design, these drives are built to endure the rigors of high-demand environments. They feature a robust construction that allows for efficient heat dissipation, minimizing the risks associated with overheating. Additionally, their form factor is designed for easy integration into various server and storage systems, making them versatile solutions for IT infrastructure.

Fujitsu's commitment to sustainability is also evident in the MAW series with their energy-efficient operation and reduced power consumption, contributing to decreased overall operational costs. With a combination of high performance, reliability, and sustainability, the Fujitsu MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP hard drives stand out as formidable choices for organizations looking to optimize their data storage solutions. They embody the cutting-edge technology and quality that Fujitsu is known for in the enterprise storage market.