Installation
11.Make the electrical connection
GROUNDING INSTRUCTIONS
THIS APPLIANCE MUST BE
GROUNDED.
In the event of a malfunction or break down, grounding will reduce the risk of electric shock by providing a path of least resistance for the electric current. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be inserteded in an appropriate outlet installed and grounded in according to local codes and ordinances.
,WARNING- An improper connection of the equipment grounding conductor can result in electric shock.
Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified electrician. If there is any question about the proper electrical connection or grounding of this appliance to the power supply, please consult a licensed electrician or call Miele’s Technical Service Department:
USA 1-800-999-1360
CDN
Specifications
The dishwasher comes equipped with a 4 ft (1.2 m) power cord with a molded plug for connection to 120 V, 60 Hz, 15 A grounded receptacle.
Rated load:. . . . . . . . . . 12.5 A / 1500 W
Voltage: . . . . . . . . . . . . . . . . . . 120 VAC
Frequency: . . . . . . . . . . . . . . . . . . 60 Hz
Circuit breaker:. . . . . . . . . . . . . . . . 15 A