6.4.3Troubleshooting at the repair site

For maintenance at this level, we recommend additional testing of the disk drive and signal checking.

The sense data posted from the HDD helps with troubleshooting. This sense data makes the error type clear (functional, mechanical, or electrical error). Chapter 7 error analysis by sense data, and gives supplementary information on finding the error cause (faulty part).

Table 6.3 lists how to detect a faulty disk drive subassembly. This fault finding requires a working host computer or disk drive test equipment to recreate the error conditions.

If the detected error cannot be recreated in an ordinary test, disk drive conditions can be changed to force the error to recur. This is done by changing the DC voltage or the ambient temperature of the disk drive.

If the error does not recur with changed conditions, the disk drive is not faulty. If no error occurs in the disk drive test, notify the user of the test results, and find out from the user the environment conditions where the disk drive is used.

 

Table 6.3

Disk drive troubleshooting

 

 

 

 

Item

 

 

Recommended action

 

 

 

Frequent or repeated seek errors

 

Collect sense data, and see Chapter 7.

 

 

Replace the disk drive, and check that the test method is correct. If the

 

 

error recurs, it is likely that the disk drive is normal but the test method

 

 

is incorrect.

 

 

 

Intermittent or nonfatal errors

 

Replace the disk drive, and check that the test method is correct. If the

 

 

error recurs, it is likely that the disk drive is normal but the test method

 

 

is incorrect.

 

 

To check performance, change the disk drive conditions by changing

 

 

the voltage or temperature.

 

 

 

 

If the disk drive error recurs or a possibly faulty part is found by troubleshooting, return the complete disk drive to the factory for repair. A media defect list must be included with the disk drive returned to the factory.

If the possibly faulty part is the disk enclosure, return the whole disk drive to the factory for repair. Also if a clear error (erroneous servo track information or noisy drive) is detected in the disk enclosure, return the whole disk drive to the factory. A media defect list must be included with the disk drive returned to the factory.

CAUTION

Damage

1.Never remove any labels from the drive.

2.Never open the disk enclosure for any reason. Doing so will void any warranties.

6-14

C141-E226

Page 110
Image 110
Fujitsu MAW3147NC/NP, MAW3300NC/NP, MAW3073NC/NP manual Troubleshooting at the repair site, Disk drive troubleshooting

MAW3147NC/NP, MAW3073NC/NP, MAW3300NC/NP specifications

Fujitsu has established itself as a key player in the world of hard disk drives, and their MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP models showcase exemplary engineering and innovative technology. These drives are designed primarily for enterprise applications, providing robust performance, reliability, and data integrity in demanding environments.

One of the standout features of the Fujitsu MAW series is its high storage capacity. The MAW3073NC/NP model comes with a generous 73 GB capacity, while the MAW3300NC/NP boasts 300 GB, and the MAW3147NC/NP offers 147 GB of storage. This range makes them suitable for various applications, from databases to data-intensive software.

The drives utilize the latest Serial Attached SCSI (SAS) interface, which ensures high speed and efficiency in data transfer. SAS technology provides better bandwidth and performance compared to older parallel SCSI interfaces, enabling faster access to data and improved overall system responsiveness. With rotational speeds of 10,000 RPM, these drives further enhance performance, enabling faster read and write times, which is critical for enterprise applications that require quick data retrieval.

Another noteworthy characteristic of the Fujitsu MAW series is their advanced error recovery and data integrity features. The drives are equipped with sophisticated error correction mechanisms and management systems that help maintain data integrity, ensuring that the data remains intact even in the event of power loss or system failure. This reliability is paramount for enterprise environments where data loss can result in significant operational disruptions.

In terms of physical design, these drives are built to endure the rigors of high-demand environments. They feature a robust construction that allows for efficient heat dissipation, minimizing the risks associated with overheating. Additionally, their form factor is designed for easy integration into various server and storage systems, making them versatile solutions for IT infrastructure.

Fujitsu's commitment to sustainability is also evident in the MAW series with their energy-efficient operation and reduced power consumption, contributing to decreased overall operational costs. With a combination of high performance, reliability, and sustainability, the Fujitsu MAW3073NC/NP, MAW3300NC/NP, and MAW3147NC/NP hard drives stand out as formidable choices for organizations looking to optimize their data storage solutions. They embody the cutting-edge technology and quality that Fujitsu is known for in the enterprise storage market.