8. Appendix
8.1Relevant Image Scanner Specification
Product:fi-4010CU
Type:Desktop
Image sensor: | Reduced optical system |
Operating method: | Document fixed Flat bed, Automatic Document Feed (ADF), |
| |
Light source: | Fluorescent tube (White) |
Basic resolution: | 600 dpi |
Output resolution1: | 50 dpi to 600 dpi (at steps of 1dpi) |
Grayscale levels (internal): | 8 bit 256 levels |
Grayscale output: | Enabled (8 bits) |
Halftone Patterns: | Dither matrix (1 pattern) |
Color (24bit) output: | Enabled |
Flat bed scanning speed: | Monochrome 8 sec or less (A4, 200 dpi) |
| Color 10sec or less (A4, 150dpi) |
ADF scanning speed 2: | Monochrome, Single sided: 10 pages per minute (200 dpi, A4, |
| 80g/m2) |
| Color, Single sided: 3.3 pages per minute (150 dpi, A4, 80g/m2) |
ADF paper chute capacity: | Maximum 25 sheets (A4, 80g/m2, High quality paper, normal |
| temperature and humidity) |
Document size: | Flat bed Maximum 210 mm x 297 mm |
| ADF Minimum 114mm x 140 mm |
| Maximum 216 mm x 355 mm |
Supported regular paper 3: | A4, A5/A5 Landscape, A6/A6 Landscape, B5, |
| B6/B6 Landscape, Letter, Legal, US Executive, Name card |
Scanning area specification: | Specified (one location) |
White level follower: | Disabled |
Brightness / Threshold / Contrast : 255 steps | |
High light / Shadow : | 255 steps (at Color / Grayscale scanning) |
Gamma pattern: | Internal types are not available. (cannot be downloaded) |
| At custom specification, entering a value enables to set a pattern. |
Image processing function: | Reverse image, |
1. Change processing is done inside the driver.
2. This speed is only specified for the scanner itself. The actual reading speed may vary depending on the system configuration.
3. Not all paper sizes can be used in all devices. For details, refer to the users' manual for the device.
For other paper sizes, the customer settings can be used.