4. INSTALLATION OF ARP-10 (OPTION)
NOTICE
This option is not available with 48 rpm scanner unit.
4.1 Necessary Parts
Name | Type | Code No. | Qty | |
|
|
|
| |
18P9007 | 1 | |||
|
|
|
| |
Spacer | 4 | |||
|
|
|
| |
Spring Washer | M3 C5191W | 4 | ||
|
|
|
| |
Pan Head Screw | M3x8 C2700W | 6 | ||
|
|
|
| |
Pan Head Screw | M3x8 | 3 | ||
w/washer* | SWRM10 | |||
|
| |||
|
|
|
|
*Not used.
4.2 Mounting
1. Turn off the power. Remove the cover from the display unit as follows:
1 Unfasten four binding screws (M4 x 10).
2 Unfasten six binding screws (M3 x 10).
3 Remove three rubber covers to unfas- ten three hex nuts.
4 Loosen two hex nuts.
11
2
2
4
1 | 3 | 1 |
Figure 4-1 Display unit, rear view
2.Fasten the
(1)Attach three spacers.
(2)Attach the P107 connector from the
(3)Faster the
Front
Spring Washer
M3 3 pcs.
$
Spacer
$
Pan Head
Screw
M3 x 8 3 pcs.
P107
J107
18P9007
SPU Board
SPU9211
Note: Remaining hardware may be discarded.
Figure 4-2 How to mount the
4.3 Adjustments
Input signal
1.Connect the gyrocompass. Turn on the radar and transmit.
2.Press the [MENU] key and select the OTHERS menu
3.Select “23. Self Test” and press the [ACQ/ ENTER] key. Confirm that the
Video signal
Confirm the following on the
•Video is “OK.”
•Adjust the GAIN, A/C and A/C RAIN con- trols so