Furuno 1944C, 1954C, 1964C Jumper block, slide switch setting, Power supply unit, inside view

Models: 1824C 1934C 1954C 1834C 1964C 1944C

1 91
Download 91 pages 5.55 Kb
Page 44
Image 44

Jumper block, slide switch setting

The jumper block JP1 and slide switch S112 on the PWR board (03P9419) must be set according to radar model. Open the unit, locate JP1 and S112 and set them as below.

Jumper block JP1 ("open" for this radar; leave the dummy connector attached)

Slide switch S112 (Downward position for this radar)

FR-8252

S

S112

T

MODEL1964C

Power supply unit, inside view

Jumper block, slide switch

Function

Setting

JP1

Enables/disables motor slow start circuit.

Open (enable)

S112

TUNE voltage selector (0-12 V, 0-32 V)

Downward position

 

 

(0-32 V)

2-8