Furuno 1964C, 1954C, 1944C, 1934C Checking Magnetron Heater Voltage, MODEL1824C MODEL1834C

Models: 1824C 1934C 1954C 1834C 1964C 1944C

1 91
Download 91 pages 5.55 Kb
Page 61
Image 61

3.2 Checking Magnetron Heater Voltage

Magnetron heater voltage is formed on the MD (1824C), PTU (1834C) or RTB (1934C/1944C1954C/1964C) Board of the antenna unit, and preadjusted at the factory. Therefore, no adjustment is required. However, check magnetron heater voltage for confirmation as shown below. This procedure should only be performed by a qualified technician.

1.Open the antenna unit.

2.Turn on the power. Do not transmit the radar.

3.Connect a multimeter, set to 10VDC range, appropriate position on the MD (1824C), PTU (1834C) or RTB (1934C/1944C1954C/1964C) Board in the antenna unit. Refer to the table in below.

4.Confirm that the multimeter indication is within the ratings shown below.

 

MODEL1824C

MODEL1834C

MODEL1934C/1944C/

 

 

 

1954C/1964C

Check point

TP804#6 (+) and #4

TP802#4 (+) and #6 (-)

J825#4 and #6 (GND) on

(-) on MD Board

on PTU Board

RTB Board

 

Multimeter

7.9 to 8.1 V

7.4 to 7.6 V

7.4 to 7.6 V

indication

 

 

 

Adjustment point

VR801 on MD Board

R106 on PTU Board

VR801 on MD Board

3-15