SYSTEM CONFIGURATION

RADIATOR SN30AF SN36AF

ANTENNA UNIT

CHASSIS

RSB-111/112

 

 

 

 

 

 

 

 

POWER SUPPLY UNIT

 

 

 

 

PSU-006

 

 

 

 

 

 

 

 

200 VAC, 3φ, 50 Hz (For amtenna motor)

 

 

 

220 VAC, 3φ, 60 Hz

 

 

 

 

 

380 VAC, 3φ, 50 Hz

 

 

 

 

 

440 VAC, 3φ, 60 Hz

 

 

 

 

 

110 VAC, 3φ, 60 Hz

TRANSFORMER

 

 

 

RU-5693

 

 

 

 

 

 

 

220 VAC, 3φ, 50 Hz

TRANSFORMER

 

 

 

RU-6522

 

 

 

 

 

 

 

440 VAC, 3φ, 50 Hz

TRANSFORMER

 

 

 

RU-5466-1

 

 

 

 

 

 

 

 

(For high voltage)

 

 

 

100-115V/220-230 VAC

 

 

 

1φ, 50/60 Hz

TRANSFORMER

 

 

 

440 VAC, 1φ,

 

 

 

RU-1803

 

 

 

50/60 Hz

PROCESSOR

 

 

 

 

 

Navigator

IEC-61162 Serial data

 

UNIT

(I/O)

RPU-013

 

Speed Log IEC-61162 Serial data

 

 

 

 

(Input)

 

 

 

Gyrocompass

GYRO CONVERTER

 

 

 

 

GC-10

 

AD-100

 

 

 

AIS

Track Controller

MEMORY CARD

INTERFACE UNIT

CU-200-FAR

MONITOR UNIT

MU-201CR

or

MU-190

CONTROL UNIT

RCU-014

(Standard)

OR

RCU-015

(Trackball)

CONTROL UNIT

RCU-016

Radar Remote

Display

SWITCHING HUB

HUB-100

Alarm

VDR

External

Monitor

TRANSFORMER

RU-1803

*

100-230 VAC

1φ, 50/60 Hz

100-115 VAC/

: Standard supply

220-230 VAC

: Optional supply

1φ, 50/60 Hz

: Local supply

 

* FAR-2167DS-BB is not equipped with a monitor unit. Procure one locally.

 

440 VAC

 

1φ, 50/60 Hz

Equipment category

 

 

Unit

Category

 

 

Antenna

Exposed to weather

 

 

Other units

Protected from weather

 

 

iii

Page 5
Image 5
Furuno 2167DS-BB, FAR-2167DS installation manual System Configuration, Iii