7.Using the terminal opener provided, connect cores (except coaxial cable) to their appropriate locations on TB801 on the TB Board. Refer to the interconnection diagram for wiring details.

8.Connect the coaxial cable to TB802, referring to the right-hand illustration below..

Wiring WAGO connector Push down.

Terminal opener

Fastening coaxial cable

Fasten shield by clamp.

Wire

Twist

Procedure

WAGO connector

Taping

Fasten conductor with screw.

 

NOTICE

1.Twist core.

2.Insert terminal opener as shown and push down.

3.Insert core into hole.

4.Release terminal opener.

5.Pull wire to confirm that it is firmly in place.

Fasten BARE conductor. Do not use crimp-on lug, to prevent increased contact resistance.

How to wire WAGO connector

9.Attach crimp-on lug (FV5.5-4) to the shield of the signal cable and fasten it with the screw at the location specified in the illustration on the preceding page.

10.Process unused cores as follows:

a)Slip shrink tubing onto cores and heat.

b)Bind unused cores with cable tie.

11.Unfasten the gland nut for the HV cable and remove gasket, flat washers (3 pcs.) and gland cap. (The gland cap may be discarded.)

12.Fabricate the HV cable as shown below.

20 mm

6

Armor

5 mm

 

 

 

Sheath

 

Sheath

L

 

 

Vinyl

Armor

Conductor

sheath

L: 300 mm (red)

S = 1.50 mm2

φ = 1.56 mm

 

 

L: 370 mm (black, white)

 

 

 

SECTIONAL VIEW

How to fabricate HV cable TYPCY-1.5

2-4

Page 28
Image 28