Furuno FR-2155 manual Power supply unit PSU-001, Fabrication of power cable and signal cable

Models: FR-2155

1 89
Download 89 pages 40.2 Kb
Page 34
Image 34

Power supply unit PSU-001

Two cables run to the Power Supply Unit PSU-001, the power cable (DPYCY- 3.5) and the signal cable (660V-MPYCY-16). The figure below shows the loca- tion of the terminal boards inside the PSU-001. Wire the unit as shown in the interconnection diagram.

5Vinyl sheath

 

 

 

 

 

ANTI-CORROSIVE

 

 

 

 

 

SHEATH

 

 

Armor

150 mm

 

 

10

5

Vinyl sheath

 

 

 

 

 

 

 

 

 

Vinyl tape

Crimp-on lug

 

 

 

 

 

 

 

 

FV5.5-4

 

Armor

Vinyl tape

 

Clamp here.

 

 

 

Clamp here.

 

 

 

 

 

 

Power Cable DPYC-3.5

 

Signal Cable 660V-MPYCY-16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Core No.

 

Connected to

 

Crimp-on Lug

 

 

 

 

 

 

 

 

 

 

 

 

 

1 to 9

 

PTB2

 

FV1.25-M3 (Red)

 

 

 

 

 

 

 

 

 

 

 

 

 

10 to 16

 

PTB1

 

FV2-4 (Blue)

 

 

 

 

 

 

 

 

 

 

 

Figure 2-16 Fabrication of power cable and signal cable

PTB2

PTB1

Cable clamp

Figure 2-17 Power supply unit PSU-001

2-12

Page 34
Image 34
Furuno FR-2155 manual Power supply unit PSU-001, Fabrication of power cable and signal cable