Furuno MFD8/12/BB manual 1.1.MFD8/12 Mounting

Models: MFD8/12/BB

1 101
Download 101 pages 58.73 Kb
Page 11
Image 11
1.Mounting

1.Mounting

1.1.MFD8/12 Mounting

MFD8

MFD12

When selecting a mounting location for the NN3D MFD8/12, keep the following in mind:

The temperature and humidity of the mounting location should be moderate and stable.

Install the unit away from exhaust pipes and ventilators.

The mounting location should be well ventilated.

Mount the unit where shock and vibration are minimal.

Keep the unit away from electromagnetic field generating equipment such as motors and generators.

For maintenance and checking purposes, leave sufficient space from the sides and the rear of the unit and leave slack in cables. Minimum recommended space is shown the outline drawing for the display units.

•Test and Confirm that the Operator LCD Viewing Angle, which is fixed, is acceptable before permanent MFD8/12 installation. This is very important for Flush Mount Installations!

A magnetic compass will be affected if the display unit is placed too close to it. Observe the compass safe distances shown in the SAFETY INSTRUCTIONS to prevent disturbances to the magnetic compass.

The MFD8/12 can be flush or bracket mounted in a variety of ways.