Control channel 5 - Gobo rotation
Feature | ||
No rotation | ||
Forwards gobo rotation with decreasing speed | ||
Backwards gobo rotation with increasing speed | ||
Control channel 6 - Shutter, strobe |
Feature | |
Shutter closed | |
Dimmer control | |
Reset (after | |
No function (Shutter open) | |
Strobe effect with increasing speed | |
Random strobe effect with increasing speed | |
No function (Shutter open) |
CLEANING AND MAINTENANCE
The operator has to make sure that
The operator has to make sure that
The following points have to be considered during the inspection:
1)All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded.
2)There must not be any deformations on housings, fixations and installation spots (ceiling, suspension, trussing).
3)Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material abrading or damages) and must not rotate with unbalances.
4)The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a moist,
CAUTION!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
The objective lens will require weekly cleaning as
The gobos may be cleaned with a soft brush. The interior of the fixture should be cleaned at least annually using a
The dichroic
To ensure a proper function of the
14/1551839250X62NXS_V_1_1_E.DOC