Garland CG-60F INSTALLATION Continued, General Information, Legs, Casters & Leveling, Clearances

Models: CG-60F CG-48F CG-72F

1 12
Download 12 pages 35.12 Kb
Page 5
Image 5
INSTALLATION Continued

INSTALLATION Continued

We suggest installation, maintenance and repairs should be performed by your local authorized service agency listed in your information manual pamphlet..

In the event you have any questions concerning the installation, use, care or service of the product, write or call our Product Service Department..

This product must be installed by professional personnel as specified.. Garland/U..S.. Range products are not approved or authorized for home or residential use, but are intended for commercial applications only.. Garland / U..S.. Range will not provide service, warranty, maintenance or support of any kind other than for commercial applications..

General Information

Damage Check: check carton or crate for possible damage incurred in shipping.. After carefully examining, check for “concealed” damage.. Report any damage immediately to your carrier..

Legs, Casters & Leveling

1.The unit must be installed on the legs or casters provided.. A minimum 4 inch (101 mm) air space must be maintained below the unit for required air flow to the burner systems.. Avoid placing any objects under the unit which could obstruct air flow to the burner systems..

2.For models equipped with casters,the installation shall be made with a connector that complies with the Standard for Connectors for Moveable Gas Appliances, ANSI Z21..69/CSA 6..16, Addenda Z21..69B-2006/CSA 6..16B-2006 (or latest edition), and a quick-disconnect device that complies with the Standard for Quick Disconnects for Use with Gas Fuel, ANSI Z21..41/CSA 6..9, Addenda Z21..41A- 2005/CSA 6..16A-2005 (or latest edition)..

3.Adequate means must be provided to limit movement of the appliance without depending on the connector and quick disconnect device or associated piping.. This can be accomplished by attaching restraining chains/cables from floor or rear wall to rear of unit..

Ensure front casters are kept in the locked position except when the unit must be moved for cleaning or servicing, etc..

4.When the unit is installed in its operating location, level the unit by adjusting the leveling legs.. Use a level across the front rear, and sides of each unit..

NOTE:  The griddle plate may not rest evenly on the unit body if the unit is not properly leveled..

5.. Each caster has a threaded stem

1/2"

to aid in leveling only.. No caster

(13mm)

MAX

should be adjusted beyond

 

amaximum of one-half inch, (1/2”/13mm) of exposed thread with the locking nut tight against the stand leg, as shown..

Clearances

This unit must be installed in accordance with the following clearances in order to provide proper operation and servicing of the appliance..

Clearances

 

Sides

Back

 

 

 

Left

 

Right

 

 

 

Combustible

6”

 

6”

6”

(152mm)

(152mm)

(152mm)

 

Noncombustible

0”

 

0”

0”

 

 

 

 

 

Service

 

Not Required

 

 

 

Type of Floor or Base

 

Combustible

 

 

 

 

 

Gas Connections

1.A readily accessible gas shut-off valve is provided on each unit, attached to the main manifold under the unit.. The gas supply connection must be made with minimum 3/4 inch NPT pipe.. Larger than 3/4 inch (19 mm) supply pipe may be required when a long run of supply pipe

is necessary.. Consult the pipe capacity tables in the installation code..

2.Have a qualified gas technician check the gas pressure to make certain that the existing gas facilities (meter, piping, etc..), will deliver the BTU’s of gas required at the unit, with no more than 1/2 inch (12 mm) water pressure drop.. When checking pressure, be certain that all the equipment on the same gas line is turned “ON”..

3.The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG.. (3..45 KPA)..