Garland CG-48F Operation Instructions, Adjustments, Lighting Instructions, Shut Down Instructions

Models: CG-60F CG-48F CG-72F

1 12
Download 12 pages 35.12 Kb
Page 7
Image 7
OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS

Lighting Instructions

1.First, make certain that the main power switch is set to “OFF”

2.Connect an electrical power cord to 120 volt supply..

3.Turn the gas shut off valve to the “OPEN” position (valve handle in line with piping)..

4.Turn the main power switch to “ON”, power switch green indicator should illuminate.. Wait until gas pilot, green indicator illuminates followed by the main burner amber light indicator..

NOTE:  Should pilot ignition fail after a few minutes turn the main power switch to “OFF”..

Wait 5 minutes, then turn the main power switch back to“ON”..

5.When the green indicators for their respective zones are illuminated, set the thermostats to the desired temperature settings..

6.The amber burner indicators cycle with the thermostat operation..

Note: During an electrical power interruption, turn power switch to the “OFF” position.. This unit cannot be made to operate without electrical power..

Shut Down Instructions

1.Turn main power switch to “OFF” (thermostat dial settings may be left at their set point if preferred) at the end of daily operations..

2.For extended shut down, turn main power switch to “OFF”, close the manual gas shut off valve and unplug the electrical cord set..

NOTE:  Do not waste gas or abuse equipment by leaving thermostats at a high temperature setting, if not required.. During idling periods, set thermostats to a low temperature setting.. For example 175°F (79°C) to 200°F ( 93°C), to keep griddle warm.. Set thermostats, as required, for periods of heavy load..

ADJUSTMENTS

NOTE:  Each griddle has been factory tested and adjusted prior to shipment.. It may be necessary to further adjust the unit as part of a proper installation.. Such adjustments are the responsibility of the installer.. Adjustments are not considered to be defects in material and workmanship, and they are not covered under the original equipment warranty..

Pilot Adjustment

A pilot adjustment valve is located in the line from each pilot combination valve.. Pilot adjustment is accessible from behind the lower front panel.. First remove the two screws securing the upper front panel to the body, in the upper right and left hand corners, and then slightly raise the panel to lift off.. Remove to a safe area.. Next, remove the two screws securing the lower front panel to the body, in the upper right and left hand corners and hinge the panel downwards..

Turning the small screw in the pilot adjusting valve clockwise reduces the amount of gas provided to the pilot(s).. Turning the small screw counterclockwise increases the gas provided to the pilot(s).. The gas should be adjusted to a 7/16 (11 mm) inch long flame, to ensure that the flame engulfs the top of the flame sensor..

Burners should always be warm when an adjustment to air shutters is made.. To adjust air shutters, loosen the small screw along the side of the burner near the orifice.. Lifting flames on the burner indicates too much air and this air shutter should be in a more closed position.. Yellow tips on the flames indicate not enough air and the air shutter should be in a more open position.. When the air shutter adjustments are complete on each burner, retighten the air shutter screw so that the correct setting is locked in place..