TROUBLE SHOOTING Continued

Troubling Shooting Guide

Fault

Possible Cause

Action to take through operator or

operating personnel

 

 

No heating indicator operation is OFF

No electrical supply

Check if the electrical supply (cable

(dark)

 

plugged in the wall socket), check

 

 

preliminary fuses

 

Control in off-position

Push control on

 

Pan too small (bottom diameter less

Use a suitable pan

 

than 5” (127 mm )

 

 

Pan is not placed in the center of the

Move the pan to the center of the

 

heating area (the cooker can’t detect

heating area

 

the pan)

 

 

Unsuitable pan

Choose a pan which is recommended

 

 

for induction cooking *

 

Cooker defective

Ask your supplier for repair service,

 

 

unplug the cooker from the electrical

 

 

supply

Poor heating, indicator operation is ON

Used pan is not ideal

Use a pan which is recommended for

(shines)

 

induction cooking, compare results

 

 

with ‘your’ pan

 

Air-cooling system obstructed

Verify, that air inlet and air outlet are

 

 

not obstructed with objects

 

Ambient temperature is too high (the

Verify, that no hot air is sucked in by the

 

cooling system is not able to keep the

fan. Reduce the ambient temperature.

 

cooker in normal operating conditions

The air inlet temperature must be lower

 

**

than 40ºC/110ºF

 

One phase is missing (only with three

Check preliminary fuses

 

phase supply)

 

 

Cooker defective

Ask your supplier for repair service,

 

 

unplug the cooker from the electrical

 

 

supply

No reaction to control knob positions

Control knob defective

Ask your supplier for repair service,

 

 

unplug the cooker from the electrical

 

 

supply

Heating cycle switches off and on

Air inlet or outlet obstructed

Remove objects from air inlet and air

within minutes, fan is active

 

outlet slots, clean the slots

 

Grease filter is dirty

Clean grease filter

Heating switches off and on within

Fan defective

Ask your supplier for repair service

minutes, fan is never active

Fan control defective

 

 

 