TROUBLE SHOOTING Continued
Troubling Shooting Guide
Fault | Possible Cause | Action to take through operator or | |
operating personnel | |||
|
| ||
No heating indicator operation is OFF | No electrical supply | Check if the electrical supply (cable | |
(dark) |
| plugged in the wall socket), check | |
|
| preliminary fuses | |
| Control in | Push control on | |
| Pan too small (bottom diameter less | Use a suitable pan | |
| than 5” (127 mm ) |
| |
| Pan is not placed in the center of the | Move the pan to the center of the | |
| heating area (the cooker can’t detect | heating area | |
| the pan) |
| |
| Unsuitable pan | Choose a pan which is recommended | |
|
| for induction cooking * | |
| Cooker defective | Ask your supplier for repair service, | |
|
| unplug the cooker from the electrical | |
|
| supply | |
Poor heating, indicator operation is ON | Used pan is not ideal | Use a pan which is recommended for | |
(shines) |
| induction cooking, compare results | |
|
| with ‘your’ pan | |
| Verify, that air inlet and air outlet are | ||
|
| not obstructed with objects | |
| Ambient temperature is too high (the | Verify, that no hot air is sucked in by the | |
| cooling system is not able to keep the | fan. Reduce the ambient temperature. | |
| cooker in normal operating conditions | The air inlet temperature must be lower | |
| ** | than 40ºC/110ºF | |
| One phase is missing (only with three | Check preliminary fuses | |
| phase supply) |
| |
| Cooker defective | Ask your supplier for repair service, | |
|
| unplug the cooker from the electrical | |
|
| supply | |
No reaction to control knob positions | Control knob defective | Ask your supplier for repair service, | |
|
| unplug the cooker from the electrical | |
|
| supply | |
Heating cycle switches off and on | Air inlet or outlet obstructed | Remove objects from air inlet and air | |
within minutes, fan is active |
| outlet slots, clean the slots | |
| Grease filter is dirty | Clean grease filter | |
Heating switches off and on within | Fan defective | Ask your supplier for repair service | |
minutes, fan is never active | Fan control defective |
| |
|
|
Page 12 | Part # 4520897 (01/31/08) |