Garland Regal Series Specifications, Introduction, Uncrating, Rating Plate, Model Number, Lp Gas

Models: Regal Series

1 16
Download 16 pages 42.03 Kb
Page 4
Image 4
SPECIFICATIONS

SPECIFICATIONS

MODEL NUMBER

NATURAL GAS

LP GAS

Orifice Size

Total Input

Orifice Size

Input

 

 

 

 

 

 

RHPA-1112A

46

20,000 BTU

56

17,500 BTU

 

 

 

 

 

RHPA-212A & RHPR-12

46

40,000 BTU

56

35,000 BTU

RHPA-224A

46

40,000 BTU

56

35,000 BTU

 

 

 

 

 

RHPA-336A

46

60,000 BTU

56

52,500 BTU

 

 

 

 

 

RHPA-424A &RHPR-24

46

80,000 BTU

56

70,000 BTU

 

 

 

 

 

RHPA-448A

46

80,000 BTU

56

70,000 BTU

 

 

 

 

 

RHPA-636A & RHPR-36

46

120,000 BTU

56

105,000BTU

 

 

 

 

 

RHPA-848A & RHPR-48

46

160,000 BTU

56

140,000 BTU

Operating pressure is 5”WC for Natural Gas and 10”WC for LP Gas.

INTRODUCTION

U.S. Range manufactures the “Regal” Hot Plate in widths ranging from two feet to five feet, and either one or two burners deep, to be used as free-standing counter units.

All units are shipped completely assembled, with the pressure regulator and adjustable legs packed on the drip pan. The burners are tied to their hangers to prevent vibration damage. All units are inspected at the factory prior to shipment.

Like any fine, precision built piece of equipment, your appliance should be given regular care and maintenance. Periodic inspections by your dealer or a qualified service agency are recommended.

Uncrating

After uncrating, immediately check the equipment for visible signs of shipping damage.

If such damage has occurred, do not refuse shipment, but contact the shipper and file the appropriate freight claims.

Rating Plate

The rating plate is attached to the hot plate’s end frame. It can be viewed by tilting the unit and looking underneath. A flashlight may be necessary.

When corresponding with the factory or your local authorized factory service center regarding service problems or replacement parts, be sure to refer to the particular unit by the correct model number (including the prefix and suffix letters and numbers) and the warranty serial number. The rating plate affixed to the unit contains this information.

Other information on this plate is the BTU/hr input to the burners, outlet gas pressure in inches WC, and whether orificed for natural or propane gas.

WARNING All U.S. Range Hot Plates must be connected only to the type of gas identified on the rating plate! Installation must be in accordance with ANSI 283.11 (latest edition) of the American national Standards Institute, Inc.

Page 4

Part # 1382698 (02/26/08)

Page 4
Image 4
Garland Regal Series Specifications, Introduction, Uncrating, Rating Plate, Model Number, Natural Gas, Lp Gas, Total Input