Plug-in

Power Strip

Total Supported Devices

Configuration

 

 

 

 

 

 

 

115 VAC

15 amp

System drawer only

 

 

 

 

 

20 amp

System drawer with other

 

 

 

peripherals not to exceed a total of

 

 

 

16 amps for the whole strip.

 

 

 

 

If rack mounted units are installed in a closed or multi-rack cabinet, they may require further evaluation by Certification Agencies. The ambient temperature within the cabinet may be greater than room temperature. Make sure the amount of air flow required for safe operation is not compromised. The maximum temperature for this environment must not exceed 122° ( 50C).

Turning on the system drawer

To turn on the system drawer for the first time:

1If using a UPS, turn it on first.

2Turn on the monitor and any additional devices connected to the system drawer. Listen for alarms which may indicate power problems.

3If multiple system drawers and a switch box are installed, press the switch box button that corresponds to the system drawer being turned on.

4Press the ON/OFF button on the system drawer.

Important If multiple system drawers are installed, you must turn on each system drawer and wait for it to start completely before turning on the next system drawer.

5Listen for alarms which may indicate power problems.

6Make sure the power indicator is illuminated. The monitor should display the normal Power On Self-Test (POST) information. If the monitor does not display information or the system drawer indicates an error has occurred, refer to the server system manual troubleshooting section.

26Installation