GE 229C4053P447-3 1, 31-10463 Installation Required Clearances, Acceptable electrical

Models: 31-10463 229C4053P447-3 1

1 12
Download 12 pages 55.05 Kb
Page 4
Image 4
Installation Required Clearances

Installation Instructions

A

Installation Required Clearances

See Ilustrations below for all rough-in and spacing dimensions.

The range may be placed with 0” clearance (flush) at the back wall and side walls of the cabinet.

MINIMUM DIMENSIONS BETWEEN

**15" MIN

COOKTOP, WALLS, AND ABOVE THE

COOKTOP.

**30" MIN Acceptable electrical ***6" length is parallel to the floor.

MIN

*Make sure the wall covering, countertop

and cabinets around the range can with-

*0"

 

 

 

 

*0"

 

 

stand the heat (up to 200°F.) generated by

 

 

 

 

 

 

the range.

 

 

 

 

 

 

 

 

 

 

 

 

**Allow 30” Minimum clearance between

surface units and bottom of unprotected wood or metal cabinet, and 15” Minimum between countertop and adjacent cabinet bottom.

***Recommended spacing to heat sensitive surfaces.

Acceptable electrical

outlet area.2 1/2" Orient the electricalManual background receptacle so the

length is parallel to the floor.

36"

30"

25"

Manual background 2 1/2"

7 1/2"

NOTE: Use a 4 foot power cord to prevent interference with the storage drawer. Power cords 4.5 or 6 foot long may have to be dressed to allow for proper drawer closing.

4

Page 4
Image 4
GE 229C4053P447-3 1, 31-10463 Installation Required Clearances, Acceptable electrical, length is parallel to the floor