Depending upon your primary controller, the 45602 lamp module can be set to respond to ALL ON and ALL OFF commands in up to four different ways. Some controllers may not be able to change the response from its default setting. Please refer to your controller’s instructions for information on whether or not it supports the configuration function and if so, how to change this setting.

The four possible responses are:

-It will respond to ALL ON and the ALL OFF commands (default).

-It will not respond to ALL ON or ALL OFF commands.

-It will respond to the ALL OFF command but will not respond to the ALL ON command.

-It will respond to the ALL ON command but will not respond to the ALL OFF command.

Load Sensing

Load sensing is disabled when shipped from the factory. This feature can be enabled if desired. Setting parameter 29 to a value of 1 will enable the Load Sense function.

-Parameter No: 29

-Length: 1 Byte

-Valid Values = 0 or 1 (default 0)

Note: When replacing a burned-out light bulb, the load sensing feature (if enabled) will automatically turn the light ON when the new bulb is installed even if the Z-wave module was previously turned OFF.