Installation Instructions SafetyInstructions
About regenerating the system.
It is not hard to
Read the following carefully.
To have soft water all the time, the softener must regenerate, or recharge a certain number of times in each seven day period. How many times to regenerate (set the timer) depends on three things:
1 The number of people in your home tells you how much water is used.
2 The grains per gallon (GPG) hardness of your water supply.
NOTE: If your water supply contains iron, compensate for it by adding to the water hardness number. For example, assume your water is 15 gpg hard and contains 2 ppm iron. Add 5 to the hardness number for each 1 ppm of iron thus, making the example water hardness number 25 .
|
| 15 gpg hardness | |
2 ppm iron x 5 = 10 | +10 |
| |
(times) |
| 25 | HARDNESS NUMBER |
3 How much salt used in each regeneration is determined by the length of the fill cycle. See the Regeneration Chart section.
TroubleshootingTips Operating Instructions
CustomerService
|
| TIME/DAY |
|
| REGENERATION |
|
| TIME |
AM |
| REGENERATION |
MO WE | SA | DAY |
|
SET/CLEAR
TOUCH | VACATION ON/OFF | ||
REGENERATE NOW | |||
HOLD |
| ||
|
|
Suggested days to regenerate
2.Fill Cycle minutes needed
16
Setting the Timer for Days and Fill Minutes of Regeneration
NOTE: The timer is factory set for Monday, Wednesday and Saturday with regenerations starting at 2:00 AM. Fill time is factory set for 16 minutes.
1 Set days and time of regeneration or recharge.Step
NOTE: See Automatic Bypass section, when choosing a regeneration starting time other than 2:00 AM.
Step
NOTE: Press SET/CLEAR and quickly release to move the display ahead 1 hour at a time. Or, hold the SET/CLEAR button to move display ahead 2 hours each second.
Step
Step
Step
Step
Step
NOTE: You may get hard water between regenerations if you set the timer for fewer fill minutes than the Regeneration Chart shows you to set. A higher setting than needed will waste salt.
NOTE: Press SET/CLEAR and quickly release to move the display ahead 1 minute at a time. Or, hold the SET/CLEAR button to move the display ahead 2 minutes each second. The