Installation instructions.

Typical Installation Illustration

Fig 1. Soft water

MAIN WA

 

TER

 

PIPE

Typical Installation Illustration Hard water

Operating Instructions Installation Instructions

120-volt outlet

24V transformer

Salt hole cover removed

SALT MAIN WAOperating Instructions Installation Instructions GOES HERE TroubleshootingTips

Brinewell Optional 3-Valve Bypass Installation IllustrationPIPE

Manual background Hard water to outside faucets

Installation nut (2)

Copper tube, 3/4(2)

Washer (2)

Bypass Valve

• Pull out for service

• Push in for bypass

NOTE: Threads on the bypass valve are 1male pipe. If 1

pipes are needed, do not use the

INLETcopper tubes and nuts included. Buy adapters and plumb directly to the 1threads.

NOTE: See Drain Hose

Connections section.

CROSS-OVER

Use if water supply flows from the left.

Include single or 3-valve bypass.

Hard water

Soft water

From softener outlet

To softener inlet

TroubleshootingTips

Optional 3-Valve Bypass Installation Illustration

Adapters for this installation are not supplied with the softener. To order these adapters, call GE Parts 800.626.2000.

Fig 2.

Soft water

Bypass valve

MAIN WA

Hard water to outside faucets

 

TER

 

PIPE

Hard water

 

CustomerService

120-volt outlet

24V transformer

6

Inlet valve

Outlet valve

3-valve bypass system

For soft water service:

• Open the inlet and outlet valves

• Close the bypass valve

For bypass hard water:

• Close the inlet and outlet valves

• Open the bypass valve

Manual background Nut (2)

Manual background Copper tube, 3/4(2)

Washer (2)

Installation adapter (2)

INLET

NOTE: Threads on the installation adapters are 1male pipe. If 1pipes are needed, do not use the copper tubes and nuts included. Buy adapters and plumb directly to the 1threads.

Hard water

Soft water

From softener outlet

To softener inlet

CROSS-OVER

Use if water supply flows from the left.

Include single or 3-valve bypass.