COOL Mode

Use the COOL mode with HIGH (F3), MED (F2) or LOW (F1) fan for cooling. Use the Increase / Decrease pads to set the desired temperature between 60°F and 86°F in 1°F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to a COOL setting or if turned from a fan setting to a COOL setting, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—Select the COOL mode and HIGH (F3) or MED (F2) fan with a middle set temperature.

For Maximum Cooling—Select the COOL mode and HIGH (F3) fan with a lower set temperature.

For Quieter & Nighttime Cooling—Select the COOL mode and LOW (F1) fan with a middle set temperature.

NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.

Instructions Operating Instructions

Energy Saver

The energy saver switch controls the fan.

ON—The fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. NOTE: The fan will continue to run for a short time after the compressor cycles off.

OFF—The fan runs all the time, while the compressor cycles on and off.

This switch must be set at OFF in order to use the fan settings (on the mode control).

Installation

FAN Mode

Use the FAN at HIGH (F3), MED (F2) or LOW (F1) to

Since fan only settings do not provide cooling,

provide air circulation and filtering without cooling.

a temperature setting will not be displayed.

Instructions

Vent Control

The vent control is located above the control panels.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, pull the lever toward you. To close it, push it in.

Troubleshooting

Air Direction—Side-to-Side

The side-to-side air direction is adjusted by moving the lever to the left or right.

Air Direction—Up and Down

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.